Over time, the heat stress causes cracks near weak areas such as bends or welds. The blower assembly is adjusted, balanced andor oiled as necessary. We are looking into purchasing a home with a tempstar nugm125eka1 furnace. A cracked heat exchanger allows air from the furnace blower to interfere with the flame causing it to flutter or even roll out. If using a fluorescent dye the heat exchanger is examined using a.
Heating parts, furnace heating parts, heating and air conditioning parts and air conditioning parts available to the public. Cracked furnace heat exchangers jeffersonville, in. This allows for some of the fumes from the furnace to be drawn into your living space, while the air in space can also be drawn into the combustion chamber. Should i replace my heat exchanger or buy a new furnace.
I just got an alert on these for cracked heat exchangers. Nov 30, 2011 we are looking into purchasing a home with a tempstar nugm125eka1 furnace. Tempstar backs their products with tougher warranties, like the no hassle warranty that gives you, the homeowner, a brand new replacement unit if a major component compressor, heat exchanger or outdoor coil fails. Suitable for inspecting clamshell, serpentine and tubular design heat exchangers in standard efficiency furnaces noncondensing types. A furnace with large, open heat exchanger cracks should not be operated until repairs are made.
Mar 11, 20 both of those cause the heat exchanger to heat up and cool down far more often than if the furnace was closer to the proper size for the home or, better yet, was able to use a lower stage or modulate its heat output for smaller loads. Dec 21, 2015 a damaged heat exchanger in a gas furnace is not an issue that should be ignored. This is because the flue gasses can be poisonous such as deadly carbon monoxide and contamination of the breathing air by these gasses pose a health risk. If a heat exchanger develops cracks or holes, replacement of the appliance is imminent. Im starting to smell a scam at this point, but i let him continue. The heat exchanger must have an air and gas tight seal to separate the gasses in the flue products inside the heat exchanger from the breathing air passing over the outside surface.
Broken and leaking heat exchangers are responsible for about 1,500 deaths per year in the united states, and many more people are poisoned by exposure to toxic gasses that go unfiltered by defective heat exchangers. Mar 19, 2007 the crack is open when the heat exchanger metal is at or close to room temperature. The good news is that most furnace manufacturers offer an extended parts warranty for a heat exchanger that lasts anywhere from 10 years to a limited lifetime warranty the bad news is that the parts warranty only covers the cost of the actual heat exchangernot the labor required to replace it. Overheating causes nearly all premature heat exchanger cracks. Fg9mac series modulating, variable speed blower motor 35 tall, high efficiency condensing gas furnace. It is a set of metal tubes or coils that connects to the burner assembly and ends at the vent or flue pipe. View and download tempstar fg9mac0601714a service and technical support manual online. Cracked or corroded gas furnace heat exchangers leak co and other poisonous gasses into the home living area though air ducts. It can be hard to know if your heat exchanger is cracked by merely looking at it. A cracked heat exchanger might allow products of combustion to enter the air stream. Using a narrow vacuum attachment, thoroughly clean all chambers of the heat exchanger block assembly.
He pulls off the panel, shoves a mirror inside and takes a quick 10 second peek before confirming his diagnosis that it is in fact a cracked heat exchanger and that the unit will need to be replaced. If this is true, has the replacement exchanger been reengineered to prevent this problem. The tempstar no hassle replace limited warranty is a limited warranty that gives you continued comfort with no worries, no questions. The heat exchanger is a key part of the furnace and is responsible for the actual heating of air. Over time, this can lead to metal fatigue that results in cracks and separations. Online technical support, prices, delivery and all major heating and cooling parts brands available.
Two types of furnace warranties come into play here. Bob not only knows why cracks in heat exchangers sometimes develop, but he also knows what homeowners should do when this problem occurs as well as how regular maintenance can help prevent it in the first place. In furnaces, the heat exchanger is designed to direct combustion byproducts to the exhaust flue on one side and warm air into the house on the other. Even tiny cracks can leak dangerous carbon monoxide, or co, into the home. Now, you can have a new replacement unit should a major component compressor, coil or heat exchanger fail during the no hassle period. Heat exchanger test using a penetrating dye such as magna flux. Signs your heat exchanger is cracked romaniuk edmonton. Well be more than happy to provide you with a proposal for a new furnace or replacement heat exchanger. Leaking and broken heat exchangers expose homeowners to toxic gases, which can be very dangerous to you and your family. The heat exchanger is the furnace component that heats air. It is important that the heat exchanger is taken care of as hazards can build from a faulty exchanger. Dec 08, 2009 the only really dangerous furnace was a lennox pulse because it ran with a pressureized heat exchanger and it could force co through any cracks. The furnace box is under negative pressure if the flue in not blocked. During normal use, a heat exchanger expands and contracts repeatedly as it heats up and cools down.
If your system has been diagnosed with a heat exchanger failure or crack, give us a call 8122800510 today. Features a fluorescent penetrant that allows you to identify and locate the tiniest hairline cracks in the combustion cells of gas furnaces. The crack is open when the heat exchanger metal is at or close to room temperature. What is the life span of a furnace that depends on how.
The plates get dirty and that obstacles the heat transfer, damaging the process. The safety factor is why most heating contractors handle it like they recently did with ally bean of the. Tempstar package units are primarily produced for residential and light commercial use. Signs and symptoms of a cracked gas furnace heat exchanger. Co is produced as a result of incomplete combustion. Tempstar dc90 furnace heat exchanger recall forced air. Sometimes it is better to block the producing process in order.
Nugk, nulk, nudk, ndlk, nrlf, nrgh, nrgf, nuge, ndge, nule lennox pulse furnace, built before 1190 model. If you have an iron heat exchanger, then you need to find an iron repair liquid, which uses chemical reactions to seal holes in iron. They also check for cracks in the heat exchangers that allow soot and carbon monoxide to escape into the air circulation system. A damaged heat exchanger in a gas furnace is not an issue that should be ignored. Pour a little bit of the chemical on the hole, and leave it to dry until it seals around the exchanger. The draft inducer motor draws air into the heat exchanger and then exhausts it out the flue. Even still large, open heat exchanger cracks are always a serious safety issue that must be corrected. Over time, the heat exchanger can crack or separate, allowing carbon monoxide to enter the house. Is there any way to tell if the previous owner had the exchanger upgraded already. It transfers the heat from the gas burners to the air that circulates through the system.
Heating and cooling parts ordered via secure server. Because the metal of the heat exchanger expands and then contracts as it heats and cools, the stress may eventually cause a crack to form on the exchanger. Tempstar products are manufactured in indianapolis, indiana and laverne, tennessee. Press this onto the furnace heat exchanger, and allow it to dry. The author has been in the industry for years as a trainer for hvac technicians. I sent a short answer, but thought this was deserving of a longer answer in the form of a blog post. Please read this article about why heat exchanger cracks do not allow carbon monoxide into the house. A cracked heat exchanger is one of the most serious issues that your furnace can develop.
Located in the center of the furnace, it is where fire, gas and heat connect. If using a fluorescent dye the heat exchanger is examined using a uv or black light. Dec 07, 2011 my tempstar 7000 gas furnace is 19 years old. Its comprised of a set of tubes or coils that repeatedly loops through the airflow inside the furnace to heat the air. Dec 02, 2015 overheating causes nearly all premature heat exchanger cracks. So any cracks in the heat exchanger would only increase the amount of heat loss out of the house when the furnace is off and if the furnace was on flue gas intering the house would be as likely as a fish swimming up niagra falls. The only really dangerous furnace was a lennox pulse because it ran with a pressureized heat exchanger and it could force co through any cracks. A cracked heat exchanger is pretty serious, as far as safety for your home goes.
The heat exchanger is the critical furnace component where hazardous combustion fumes are separated from the warmed air that gets circulated through a home. If this is not effective, a thorough check of the furnace heat exchanger should be done. Heat exchanger crack finder solution, heat exchanger. In this article we discuss residential forced warm air furnace heat exchanger life in more detail, explaining the factors that impact the life of the heat exchanger, things you should do to maximize the life of the furnace heat exchanger, and similarly, things you should not do because they are likely to destroy your furnace before its time. I had a new timer board installed this summer because the furnace.
The heat exchanger in your hvac helps to transfer heat from the furnace to the air flowing through the ductwork. When a furnace cannot get enough airflow, the heat exchanger overheats and suffers excess stress from expansion and contraction. A co test should is performed, and co detectors are tested. Carrier common furnace problems premature heat exchanger. Bob not only knows why cracks in heat exchangers sometimes develop, but he also knows what homeowners should do when this problem occurs as well as how regular maintenance can.
Signs that your hvac system needs replacing networx. Remember to plug your furnace back in and turn it on once you have finished cleaning and vacuuming the heat exchanger. Heating contractors and service people have specialized equipment that tests combustion efficiency and removes soot from the heat exchanger. Carrier high efficiency gas furnace heat exchanger issues one the most common issues found in carrier high efficiency gas furnaces is corrosion or blockage is their secondary heat exchangers in approximately 5 to 10 years after the original installation date or in other words premature secondary heat exchanger failure. Another heat exchanger killer is airflow, or more specifically, a lack of it. Can you repair a cracked heat exchanger on a gas furnace. The most common cause of an overheated heat exchanger is as simple as a. Tempstar warranty information tempstar dealer locator. F96ctn ion series twostage variablespeed gas furnace. Danger of a furnace with a cracked heat exchanger servicemax. A damaged heat exchanger in a gas furnace is potentially dangerous to a homes occupants and should not be ignored. The home inspector said that this model of furnace is known to have problems with the heat exchanger cracking. Carbon monoxide is a byproduct of incomplete combustion of fuels such as petroleum and wood.
Beware of an unethical technician who finds a crack with a camera on a furnace that seems to be running just fine. A flame roll out will occur when the crack opens far enough. What causes excess soot buildup in a propane furnace. With the majority of the cracked heat exchangers that ive seen, ive always been curious how the exhaust gas from the furnace could possibly leak out of those tiny cracks enough to contaminate the househouse air. The cracks do not get better, eventually, it must be replaced. The pressure switch senses a pressure change and closes a switch to signal the control board that the furna. The heat exchanger is inspected for cracks and corrosion. Using a vacuum will help ensure that all of the debris you loosened off of the assembly is removed. Corrosion because of reaction between the combustion gas and the metal often because of improper venting can also weaken the metal to the point where cracks. A damaged or cracked heat exchanger is the cause of the leading cause of carbon monoxide poisoning in north america. O heat exchangers cracking at curve o these are older furnaces brand. Dec 02, 2014 i recently had a reader email this question. Most tempstar, heil, intertherm all icp products had this issue. The shape of the coils depends on the type or model of your furnace.
Both of those cause the heat exchanger to heat up and cool down far more often than if the furnace was closer to the proper size for the home or, better yet, was able to use a lower stage or modulate its heat output for smaller loads. In the event that it is cracked, a bridge is created between these two areas. If the draft inducer motor is defective, it may be unable to close the pressure switch, causing the ignition process to stall and the furnace to shut off after a few. Select tempstar heating and cooling products provide a onetime equivalent unit replacement if the compressor, outdoor coil, evaporator coil fan coils only, or heat exchanger should fail during the no hassle replacement limited warranty period, which varies in length of coverage from 1 to 10 years to the original purchaser.
The cause of cracked heat exchangers avoid this common scam. Since this is a system problem in tranes and the heat exchanger cracks and fails. I have a new secondary heat exchanger which needs to be installed because the plastic tank is cracked in the original exchanger. Furnace parts, heat and ac parts and ac parts for doityourself repairs.
The heart of any gasfired furnace is the heat exchanger. My tempstar furnace will start blowing cold air, the re. Carbon monoxide is the result of unburned fuel, not the heat exchanger. This trips a safety switch and shuts down the furnace. In some rare cases, it can cause flame impingement when air from the blower enters the heat exchanger.